23 - 11 - 2024
Login Form



 


Share this post

Submit to FacebookSubmit to TwitterSubmit to LinkedIn

 

TEST BED

 

 

 

 

 

 

cpuz i7 3770k

 

TESTING METHODOLOGY


   As we have stated in the past the Intel I7-3770k system is not located in our lab and so it's obviously not our primary choice when testing CPU Coolers. Still since HTPC/SFF models shouldn’t be used with our overclocked Core I7-3930k we have decided to take this path whenever one such model lands at our doorstep. As always our first concern is ambient temperatures so once again we keep the room temperature to around 21-23 degrees (not really hard but unfortunately not 100% accurate as in our lab) and as always to successfully record the load temperatures we use the latest OCCT application (for around 6-10 minutes) to push the processor to its limits so we can record its temperatures. After that is done, we wait for about 10-20 minutes for the CPU to cool down and record the idle temperatures. This is done to allow time for the thermal conductive material to achieve the optimal performance level. Same procedure was then repeated with the Passmark BurnIn Test as a failsafe just in case the OCCT results were off. As many of you have pointed out time and again this procedure takes a lot more time than the usual peltier/thermometer tests but this way not only can we deliver real world results based on real CPUs but we can also triple check the results using a variety of programs. Last but not least the temperatures are recorded using both the latest versions of AIDA64 and RealTemp while the noise level tests are performed using a high precision ExTech HD600 Decibel Meter placed about 10-15cm above the CPU Cooler.